DWA00034 – GV/NVLT Exciters

On the GV/NVLT Exciter’s Power Supply Distribution PWB (NAPC47B, B/01, C & C/01), diode CR13 has been added (Nautel part # QAP29) between U20-4 and the junction of CR10 and CR12 (anode to U20-4). This modification eliminates Exciter Reboot alarms after power cycles.